Component Manual for the Xray-Tracing Package McXtrace, version 3.8.6

8.4  The PSD_monitor McXtrace Component

Position-sensitive monitor.

Identification

Description

Based on neutron component written by Kim Lefmann An (nx times ny) pixel PSD monitor. This component may also be used as a beam detector. If instead of xwidth, yheight a radius is given, the component has a circular footprint and integrates circularly (caking).

Example: PSD_monitor(xwidth=0.1, yheight=0.1, nx=90, ny=90, filename=”Output.psd”)

Input parameters

Parameters in boldface are required; the others are optional.

Name

Unit

Description

Default

filename

str

Name of file in which to store the detector image.

0

xwidth

m

Width of detector.

0.05

yheight

m

Height of detector.

0.05

radius

m

Radius of circular detetor.

0

restore_xray

1

If set, the monitor does not influence the xray state.

1

nowritefile

1

If set, monitor will skip writing to disk

0

nx

1

Number of pixel columns.

90

ny

1

Number of pixel rows.

90

nr

1

Number of radial pixels.

0

Links

The PSD monitor

The component PSD_monitor resembles other monitors, e.g. Monitor, and also propagates the photon ray to the detector surface in the \((x,y)\)-plane, where the detector window is set by the \(x\) and \(y\) input coordinates. The PSD monitor is sensitive to the arrival position of the of the photon ray. The rectangular monitor window, given by the \(x\) and \(y\) limits is divided into \(n_x \times n_y\) pixels.

The output from PSD_monitor is the integrated counts, \(n, I, M_2\), as well as three two-dimensional arrays of counts: \(n(x,y), I(x,y), M_2(x,y)\). The arrays are written to a file, filename, and can be read e.g. by the tool mxplot, see the system manual.